Aerothermal Maintenance and Breakdowns in Madrid: What to Check and When
Aerothermal systems require mandatory annual maintenance under Spanish regulations. What the inspection includes, most common breakdowns in Madrid, warning signs and when to call a certified technician.

Aerothermal is a robust, low-maintenance system compared to combustion boilers, but it's not "install and forget". The Spanish Building Thermal Installations Regulation (RITE) requires all climate installations with a refrigerant circuit to undergo periodic maintenance. This article explains what aerothermal maintenance includes, the most common breakdowns in Madrid, and which warning signs indicate you need a technician.
Mandatory maintenance: what RITE says
RITE (Royal Decree 1027/2007 and amendments) establishes two types of maintenance:
- Periodic maintenance (annual): mandatory for all installations with nominal thermal output above 5 kW. Includes refrigerant circuit inspection, filter cleaning, leak testing and safety device verification.
- Periodic inspection: mandatory for installations with nominal output above 70 kW (every 4 years in residential buildings, every 2 years in other uses). Conducted by an authorized control body (OCA).
A typical domestic heat pump (8-16 kW thermal output) is subject to annual periodic maintenance but not OCA inspection. However, if the installation is part of a centralized building climate system, thresholds may change.
What an aerothermal inspection includes
| Component | Maintenance action | Frequency |
|---|---|---|
| Air filters | Clean or replace | Every 3-6 months (intensive use: monthly) |
| Outdoor coil (evaporator) | Clean fins and inspect fan | Annual |
| Refrigerant circuit | Leak test, pressures and refrigerant charge | Annual (RITE mandatory) |
| Expansion vessel | Check charge pressure | Annual |
| Circulation pump | Verify operation and noise | Annual |
| Safety valve | Operation test | Annual |
| DHW buffer tank | Check magnesium anode and descale | Annual |
| Sensors and thermostats | Verify readings and calibrate | Annual |
Most common aerothermal breakdowns
1. Insufficient heating output in winter
The most common complaint in Madrid during cold months. The heat pump runs but doesn't heat enough. Typical causes: low refrigerant level (circuit leak), iced or dirty outdoor coil, faulty outdoor temperature sensor, or insufficient sizing for winter demand. In Madrid, where temperatures can drop below 0°C, COP drops and an undersized system can't meet demand. See our guide on aerothermal in flats vs villas to understand sizing.
2. Ice accumulation on outdoor unit
Heat pumps periodically reverse the cycle to defrost the outdoor coil. If the defrost cycle fails, ice accumulates and drastically reduces efficiency. Causes: faulty defrost sensor, refrigerant shortage, or damaged outdoor fan. This breakdown requires technical intervention.
3. Insufficient domestic hot water
If hot water doesn't last long enough, the problem is usually in the buffer tank: scaled coil, depleted magnesium anode, or miscalibrated thermostat. Madrid has hard (limescale-rich) water, so scale accumulation in the buffer tank is a frequent breakdown that reduces DHW production capacity.
4. Abnormal noises and vibrations
Aerothermal produces normal operating sound (compressor and fan), but if metallic vibrations, knocking or intense humming appear, they may indicate: damaged circulation pump, loose outdoor unit supports, hardware loosened by vibration, or compressor at end of service life.
5. Error code on display
Modern heat pumps display alphanumeric error codes. Each manufacturer has its own table: E1, E2, F3, etc. Some errors are minor (system restart) and others require technical intervention (sensor failure, refrigerant loss, electronic board failure). If the error persists after restarting, call a technician.
Warning signs the user can detect
- Electricity bill spike with no habit change: COP has dropped, possibly due to refrigerant shortage or dirty coil.
- Takes longer to reach setpoint temperature: the system runs longer than usual to heat or cool.
- Hot water runs out sooner: scaled buffer tank or miscalibrated thermostat.
- Visible ice on outdoor unit: defrost cycle failing.
- New or different noise: mechanical component in poor condition.
- Outdoor unit never stops: possible refrigerant leak or faulty sensor.
When to call a professional
The user can clean filters and visually inspect the outdoor unit, but any intervention on the refrigerant circuit (gas recharge, leak repair, pressure checks) must be performed by a certified technician with a fluorinated gases handling certificate (F-Gas), mandatory under EU Regulation 517/2014. At AirPro Madrid, our technicians are certified and perform complete annual maintenance in compliance with RITE.
Maintenance contract: is it worth it?
An annual aerothermal maintenance contract includes the mandatory RITE inspection, filter cleaning, refrigerant circuit review and repair priority. Advantages: regulatory compliance, early breakdown detection, priority technical response and spare parts discounts. For aerothermal systems, where a winter breakdown leaves the home without heating, a contract is highly recommended.
Need maintenance or repair for your aerothermal system in Madrid?
We perform the mandatory annual RITE maintenance and repair aerothermal breakdowns with F-Gas certified technicians. On-site technical diagnosis. If you accept the repair, the diagnosis visit is deducted.
WhatsApp: Aerothermal maintenanceFrequently Asked Questions
How often should aerothermal maintenance be done?
RITE requires an annual inspection for installations above 5 kW. Additionally, air filters should be cleaned every 3-6 months depending on use. In homes with intensive use or pets, filter cleaning may be monthly.
Does aerothermal lose gas over time?
A properly installed refrigerant circuit doesn't lose gas. If there's loss, it indicates a leak that must be repaired. Refrigerant recharge is only necessary after fixing a leak. A certified F-Gas technician must perform this intervention.
Can I clean the outdoor unit myself?
You can visually check for obstructions (leaves, dirt) around the outdoor unit, but deep coil cleaning should be done by a technician to avoid damaging the fins, which are very fragile.
Why does my heat pump make more noise in winter?
In winter, the heat pump works harder (lower COP) and performs defrost cycles that generate additional noise. This is normal. If the noise is new or vibratory, it may indicate a mechanical problem requiring inspection.
Does aerothermal maintenance fall under OCA inspection?
Only if the installation's nominal output exceeds 70 kW, which is unusual for individual homes. In buildings with centralized climate control, it depends on the total system output. Annual periodic maintenance is mandatory in all cases.
Related Articles

Aerothermal in a Flat vs. a Chalet in Madrid: Which Suits You?
Aerothermal works in both flats and chalets in Madrid, but the technical solutions, space needed and investment differ significantly. Guide with real cases, indicative prices and installation requirements.

Does Aerothermal Work with Existing Radiators in Madrid?
Aerothermal can connect to existing aluminium or cast-iron radiators in Madrid homes, but key technical requirements apply: flow temperature, emission surface and unit sizing. Practical guide.

Aerothermal with Underfloor Heating and Cooling in Madrid: The Complete Guide
Cooling underfloor combined with aerothermal provides heating in winter and cooling in summer through the same circuit. Requirements, condensation, controls and indicative pricing for Madrid homes.